Expanding Foam Kits
Home | Information | Contact Us 
Sign In or Register
Browse
Eagles Guest House, "North Hykeham LINCOLN" Review
LOFT, ROOF OR ATTIC INSULATION
FREQUENTLY ASKED QUESTIONS
FROTH PAK ACCESSORIES
FROTH PAK TANKS
VIDEO SECTION
QUICK CURE VS SLOW CURE
AT A GLANCE
TECHNICAL DATA AND BULLETINS
Best Sellers
Large 600 Size  - Foam Tanks Large 600 Size - Foam Tanks
GBP £420.00
Froth-Pak Insta-Gun Hose Assembly Froth-Pak Insta-Gun Hose Assembly
from GBP £78.45
Medium 180 Size - Foam Tanks Medium 180 Size - Foam Tanks
GBP £180.00
Extra Nozzles (Pack of 25) Extra Nozzles (Pack of 25)
from GBP £18.00
Safety Goggles Safety Goggles
GBP £2.50
Gift Vouchers
Login To Purchase
A Gift Voucher
ProtX Secure Online Payments
SalePack
128bit Secure SSL
Closed-Cell Versus Open-Cell Polyurethane Spray Foam
Closed-Cell Versus Open-Cell Polyurethane Spray Foam


Polyurethane spray foam is often categorized as either "open-cell" or "closed-cell". There are several major differences between the two types, leading to advantages and disadvantages for both, depending on the desired application requirements. In addition, polyurethane spray foam is an extremely versatile material that is available in a variety of final physical properties and densities, so it is necessary for the end-user to have an understanding of these differences, and to choose the spray foam system that is best suited for the particular application requirements.

The purpose of this article is to provide a summary of the advantages and disadvantages of open-cell and closed-cell polyurethane spray foam;

Closed-cell polyurethane spray foam is among the most efficient insulating materials commercially available, with R-values commonly around 6.0 per inch.. Closed-cell foam incorporates an insulating gas that is retained within the cells (foam "blowing agent"), which leads to the highly efficient insulating properties of the material. In the U.S., insulation is measured in "R-Value" (R= resistance to heat flow), and closed-cell polyurethane spray foam has among the highest R-Values of any commercially available insulation. In addition, the closed-cell nature of this foam provides for a highly effective air barrier, low moisture vapor permeability (often referred to as the "Perm" rating), and excellent resistance to water . The most common foam density for closed-cell polyurethane foam is approximately 2.0 pounds per cubic feet. Years of research and commercial experience has shown that the 1.75 – 2.25 lb./ft3 density range provides the optimum insulating and strength characteristics for most building applications. Closed-cell polyurethane foams are usually characterized by their rigidity and strength, in addition to the high R-Value. Also, studies show that wall racking strength can by doubled or tripled when closed cell foam is applied.

Open-cell polyurethane spray foam, on the other hand, is usually found in densities ranging from 0.4 to 1.2 lbs./ft3. One of the advantages that these lower densities provide is a more economical yield, since foam density is directly related to yield (lower density = higher yield). Although the R-value of open-cell foams is slightly more than half that of closed-cell foams, usually around 3.5 per inch, these products can still provide excellent thermal insulating and air barrier properties.. Open cell foam is more permeable to moisture vapor, with perm ratings of approximately 10.0 per 4 – 5 inches thickness (up to 50 perms at one inch). However, the foam allows for a very controlled diffusion of moisture vapor whose consistency can be managed by the builder / architect. Open cell foams are incredibly effective as a sound barrier, having about twice the sound resistance in normal frequency ranges as closed-cell foam. Other characteristics of open-cell polyurethane foam usually include a softer, "spongier" appearance, as well as lower strength and rigidity than closed-cell foams.

Applications that typically use open-celled foam include residential construction insulation, under roof trusses for "conditioned attics" (especially in the South and Southwest U.S.), and for sound deadening in media rooms, etc. Closed-cell foam, while also useful in residential construction insulation, is used in a variety of commercial, industrial and residential applications because of the excellent strength and insulating properties described here.

In a "bullet point" list, the comparison of closed-cell to open-cell polyurethane foams is as follows;


Closed - Cell

      • Highest insulating "R-Value" per inch (greater than 6.0)

      • Low vapor permeability (low perm)

      • Air barrier

      • Increases wall strength

      • Resists water (is a WRB - "Water Resistive Barrier")

      • Absorbs sound, especially bass tones

      • Medium density (1.75-2.25 lbs./ft3)


Open-Cell

      • Good insulation value (R=3.5)

      • Higher vapor permeability, but controlled

      • Economical yield

      • Air barrier

      • Best sound absorption in normal noise frequency ranges

      • Low density (0.4-1.2 lbs./ft3)


This information is provided as a service and is not necessarily meant to reflect any recommendation, guideline. Each individual user must determine suitability for any particular purpose.
My Basket
Your Basket
is Empty
Special Offers
Medium 180 Size - Foam Tanks Medium 180 Size - Foam Tanks
GBP £180.00
Large 600 Size  - Foam Tanks Large 600 Size - Foam Tanks
GBP £420.00
New Products
Economy Disposable Suit Economy Disposable Suit
GBP £2.64
Deluxe Safety Suit Deluxe Safety Suit
GBP £4.99
Cured Foam Remover Cured Foam Remover
GBP £6.50
Gun Hose Rinsing Oil Gun Hose Rinsing Oil
GBP £64.62
Safety Goggles Safety Goggles
GBP £2.50
Free Delivery